4920-00-176-9236 ">
|
|
TM 55-4920-424-13&P
4-7.
INSPECTION AND MAINTENANCE INTERVALS.
4-8. Perform periodic inspection and maintenance of the items listed in figure 4-4 at the intervals indicated. During
periods of frequent use or of operation in severe climatic or environmental conditions, the inspection and maintenance
schedule should be altered accordingly.
Item
Interval
Method
Inspection and Maintenance
Battery
30 Days
Visual and
a.
Inspect vent openings for
Operational
restrictions.
b.
Check level of electrolyte.
c.
Check connections for
security of attachment.
d.
Check caps and case for
leaks and cracks.
e.
Clean corroded areas.
Note
Refer to TM-11-6140-203-15-1
when performing further
battery maintenance.
Fire Extinguisher
30 Days
Visual and
a.
Check clamp and support
Operational
bracket for security of
attachment.
b.
Check all moving parts
for corrosion and damage.
c.
Inspect horn for cracks
and chips.
(Figure
4-4
Sheet
1
of
6)
(Figure
4-4
Sheet
2
of
6)
d.
Weigh, recharge if
(Figure
4-4
Sheet
3
of
6)
required, and perform all
(Figure
4-4
Sheet
4
of
6)
inspections and mainte-
(Figure
4-4
Sheet
5
of
6)
nance prescribed by the
(Figure
4-4
Sheet
6
of
6)
manufacturer.
Figure 4-4. Table of Periodic Inspection and Maintenance (Sheet 1 of 6)