TM 55-4920-411-13&P
malfunction and cause are obvious), or is not corrected
Temperature and Speed Simulator or its components.
You should do the tests/inspections and corrective
by listed corrective actions, you should notify higher
level maintenance.
actions in the order listed.
c. Table 4-2 lists the common malfunctions that you
may find during the operation or maintenance of the
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
POWER INDICATING LAMP DOES NOT GO ON WITH SIMULATOR PROPERLY CONNECTED AND
1.
POWER AVAILABLE.
Step 1. Place POWER switch (S1) ON. Power indicating lamp should go on.
a. Replace 1/2A fuse.
b. Replace power indicating lamp.
c. Send simulator - to higher maintenance.
LAMPS L1 THROUGH L6 DO NOT TO ON WITH LAMP TEST SWITCH PRESSED.
2.
Step 1. Press LAMP TEST switch Lamps L1 through L6 should go on.
a. If lamps do not go on send simulator to higher maintenance
3.
SECONDS DISPLAY DOES NOT OPERATE WHEN START/STOP RESET BUTTON IS PRESSED.
Step 1. Press START/STOP RESET button. SECONDS counter should step through 99 then reset to 00
and continue counting.
a. If SECONDS counter does not operate, send simulator to higher maintenance.
b. If only one side of SECONDS counter does not operate, replace malfunctioning .
LED, paragraph 4-6.
Section III. REPAINTING AND REFINISHING INSTRUCTIONS
equipment is readily available prior to use.
Observe all cautions and warnings on
a. Remove dust and loose dirt with a clean, soft
c o n t a i n e r s when using consumables.
cloth, item 5, App. D.
When applicable, wear necessary protec-
tive gear during handling and use. If a
b. Remove grease, fungus and ground-in dirt with
consumable is flammable or explosive,
cloth dampened with dry-cleaning solvent, item 4, App.
MAKE CERTAIN consumable and its
vapors are kept away from heat, spark,
and flame. MAKE CERTAIN helicopter.
c. Remove moisture with a dry cloth.
is properly grounded and firefighting
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |