TM 55-1930-208-24
a. Removal. (Refer to figure 3-115).
(1) Remove ten nuts (1), ten screws (2), and ten clamps (3). Remove tube(4) and adapter (5).
(2) Remove two screws (6), gauge (7), valve (8), tee (9), tube (10), adapter (11), valve (12), nipple (13), and
elbow (14).
(3) Remove tube (15), adapters (16 and 17), two screws (18), gauge (19), and valve (20).
Figure 3-115. Pressure Gauges, Removal/Installation.
3-195
|