TM 55-1930-208-24
3-56. PRESSURE GAUGES - Continued.
b. Inspection.
(1) Inspect gauges for broken or cracked glass.
(2) Inspect tubes for bends or kinks.
c. Installation.
(1) Refer to figure 3-115 and install gauge (19) and secure with two screws (18). Install valve (20), adapters
(17 and 16), and tube (15).
(2) Install elbow (14), nipple (13), valve (12), adapter (11) and tube (10).
(3) Install tee (9), elbow (8), gauge (7), and secure with two screws (6).
(4) Install adapter (5) and tube (4). Install ten clamps (3) and secure with ten screws (2) and ten nuts (1).
3-196
|