Table 2-1. Description of Operator's-Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Motor Control Center (Figure 2-18) - continued
42
ON
Green light indicates lubricating
oil transfer pump motor running.
43
Circuit Breaker
Protects port gear oil cooling
(15 Amp)
pump motor from amperage overload.
44
Circuit Breaker
Protects starboard gear oil
(15 Amp) cooling pump motor from amperage
overload.
45
Circuit Breaker
Protects distilling plant pump
(15 Amp)
motor.
46
Circuit Breaker
Protects connection between
(150 Amp)
ship's service generator bus to
emergency generator bus for normal
operation. Failure of both ship's
service generators will open circuit
breaker. Emergency generator will only
operate mandatory emergency motor
controllers.
47
Reset Pushbutton
Resets contacts of distilling
plant motor controller.
48
Stop Pushbutton
Shuts down distilling plant.
49
Start Pushbutton
Activates distilling plant.
50
ON
Green light indicates distilling
plant pump is running.
51
Reset Pushbutton
Resets contacts of starboard gear
oil cooling pump motor controller.
52
HAND-OFF-AUTO
Three position switch, starboard gear
oil cooling pump motor. HAND position
provides continuous operation of pump
motor. OFF position will stop the pump.
AUTO allows lubricating oil tempera-
ture to start and stop the starboard
gear oil cooling pump as required.
53
ON
Green light indicates starboard
gear oil cooling pump running.