TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Motor Control Center (Figure 2-18) - continued
54
Reset Pushbutton
Resets contacts of port gear oil
cooling pump motor controller.
55
HAND-OFF-AUTO
Three position switch, port gear oil
cooling pump motor. HAND position
provides continuous operation of pump
motor. OFF position will stop the pump.
AUTO allows lubricating oil temperature
to start and stop the port gear oil
cooling pump as required.
56
ON
Green light indicates port gear
oil cooling pump running.
57
Circuit Breaker
Protects STBD ballast pump motor
(70 Amp)
from amperage overload.
58
Circuit Breaker
Protects port #1 bilge pump motor
(110 Amp)
from amperage overload.
59
Circuit Breaker
Protects port #2 bilge pump motor
(110 Amp)
from amperage overload.
60
Circuit Breaker
Protects starboard #1 air compres-
(25 Amp)
sor motor from amperage overload.
61
Reset Pushbutton
Resets contacts of air compressor
motor controller.
62
HAND-OFF-AUTO
Three position selector switch.
HAND position turns air compressor motor
on for continuous operation, OFF turns
motor off, and AUTO allows air demand to
start and stop compressor motor as
required.
63
UV RESET
Resets #1 starboard air compressor
motor controller after under voltage
condition (loss of power or low
voltage).
64
ON
Green light indicates it starboard
air compressor motor running.
65
Reset Pushbutton
Resets contacts of port #2 bilge
pump motor controller.
2-79
|