TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Motor Control Center (Figure 2-18) - continued
29
Circuit Breaker
Protects #2 port fuel oil purifier
(15 Amp) motor from amperage overload.
30
Circuit Breaker
Protects port lubricating oil
(15 Amp) purifier pump motor from amperage
overload.
31
Circuit Breaker
Protects starboard engine room
(40 Amp) supply fan motor from amperage
overload.
32
Reset Pushbutton
Resets slow run contacts of
starboard engine room supply fan motor
controller.
33
Reset Pushbutton
Resets fast run contacts of
starboard engine room supply fan motor
controller.
34
STOP SLOW FAST
Switches starboard engine room
supply fan motor to slow, stop, or fast
run condition.
35
UV RESET
Resets starboard engine room supply
fan motor controller after Under Voltage
condition (loss of power or low
voltage).
36
FAST RUN
Green light indicates starboard
engine room supply fan motor in fast
running mode.
37
SLOW RUN
Green light indicates starboard
engine room supply fan motor in slow
running mode.
38
Circuit Breaker
Protects #1 port fuel oil purifier
(15 Amp) motor from amperage overload.
39 Reset Pushbutton Resets contacts of lubricaing
t
oil transfer pump motor controller.
40
STOP
Pushbutton to STOP lubricating oil
transfer pump motor.
41
START
Pushbutton to START lubricating oil
transfer pump motor.