a. Position the thermostat, make sure the rounded "point" on the thermostat aligns with the notch on the housing.
b. Make sure that the "jiggle" pin (1, FIGURE 2-17) is in its notch (2) and the tang (3) is in the slot (4) in the
housing.
FIGURE 2-17. Thermostat Alignment.
c.
"Package" the lifting bracket (6, FIGURE 2-16) and gasket (5) to the thermostat (4) and housing (3). Install
capscrew (2) and bolts (1). Torque to 18 ft-lb (24 N-m).
d. Replace alternator (para. 2-22).
e. Connect the negative (-) battery cable and replace V belt (para. 2-21) on the alternator pulley.
NOTE
For coolant mixture, refer to TB 55-1900-207-24.
f.
Replace coolant.