TM 55-1730-228-13&P
3-21. LIMIT SWITCHES- ADJUST
3-21
This task covers:
Adjustment
INITIAL SETUP:
Tools Required
Equipment
Tool Kit TI 5180-00-177-7033
Condition
Para
Condition Description
3-17
Battery ground cable
disconnected.
Personnel Required
General Safety Instructions
MOS 63B, 1 Mechanic
Service/inspection safety brace must
be installed. Refer to para 2-13.
Figure 3-19. Limit Switch Adjustment (Sheet 1 of 2).
ADJUSTMENT:
a. With switch mounted in position, loosen socket head screw (1, Figure 3-19) on lever arm (2).
b. Use a screwdriver to turn shaft (3) clockwise until a click is heard.
GO ON TO NEXT PAGE
3-51
|