3-21. LIMIT SWITCHES-ADJUST (Continued)
3-21
Figure 3-19. Limit Switch Adjustment (Sheet 2 of 2).
c. Hold shaft (3) in position. Position lever arm (2) until it contacts the moving machine member (4) and tighten
screw (1).
d. Connect ground cable to battery. Refer to para 3-17.
e. Operate moving machine member. Click should be heard when machine member makes contact with lever
roller.
f. Operational check the switch for proper function. Readjust if necessary.