While observing the output indicator on the
3.
R E G U L A T O R PRESSURE OUTLET VALVE
(26), open the valve to the desired amount
of pressure by turning the T-handle in a
clockwise direction. When the desired amount
of oxygen has been transferred to the unit
being serviced, or when the oxygen bottle is
empty, close the valve by turning the T-handle
in a counterclockwise direction until fully
closed.
Open receiving vessel input valve by turning
4.
the valve control in a counterclockwise direc-
tion. When the desired amount of oxygen has
been transferred to the unit being serviced,
or when the oxygen bottle is empty, close the
valve by turning the valve control in a clock-
wise direction until fully closed.
SHUTDOWN.
Shutdown and disconnection of the Oxygen Servicing
3.4.1
Unit is performed as follows:
Close the receiving vessel input valve by
1.
turning the valve control in a clockwise
direction.
2.
If the bottle pressure outlet valve was used,
close by turning the valve control in a
clockwise direction until fully closed. If
the regulator pressure outlet pressure
valve was used, close by turning the valve
control in a counterclockwise direction
until fully closed.
3.
Close the valve of the oxygen bottle by
turning the knob in a clockwise direction
until fully closed.
Moisture, dust, or other con-
taminants must be kept from in-
put and output connections which
will come into contact with oxygen.
|