TM 9-6685-202-14
Figure 4-8. Disassembly of platform assembly.
(6) Remove contact screw (15), hex nuts (16)
f. Platform Assembly. Perform the following steps
and (17), recover contact spring (18), and contact
to disassemble the platform assembly for utilization of
bushing (19) from its mounting on an internal rib of the
authorized replacement parts.
platform to free electrical items which are connected to
solderless wire terminal (20) and insulated wire (21).
(1) If it is necessary to replace either of the
(7) Remove two cable clamps (22) secured to
two levels, remove level cover (1) by removing two
under side of platform by screws (23).
binding head screws (2). Chip out plaster (3) in which
(8) Remove push button switch (24) by
the level is set and remove bubble level (4).
removing binding nut (25).
(2) Remove three leveling screws (5) from
(9) Remove receptacle assembly (26) which
the platform.
is composed of receptacle (A), nut (B), insulator (C), and
(3) Remove calibration cover (6) and
insulator nut (D) from the underside of the platform.
calibration chart (7) by removing four binding head
(10) Do not remove identification plate (27)
machine screws (8).
unless illegible or damaged, to avoid losing identity of
(4) Remove drawer (9), and remove drawer
barometer. If nameplate is to be replaced, remove four
knob (10) secured by binding head machine screw (11).
socket head machine screws (28) attaching it to platform
(5) Remove battery screw (12), slide battery
(29).
case tube (13) out of its place in the base, and remove
battery case plug(14).
4-20
|