Table 5-2. TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM (CONT)
5. 115-V LAMP ILLUMINATES, BUT 24-V LAMP
DOES NOT.
Replace the 24-V electrical power cord
adapter assembly (9) with one known to
be good.
If lamp illuminates,
replace defective 24-V
electrical power cord
adapter assembly. If
lamp doesn't illumi-
nate, repair the adapter
tube assembly. (pages
6. M3 BORESCOPE COMPONENTS (12) WILL NOT
REMAIN TOGETHER.
Ensure the M3 Borescope is properly
assembled. (Refer to chapter 2,
Repair or replace any
defective lock assemblies
(13).
Section V. MAINTENANCE PROCEDURES
accomplished only to the extent necessary to facilitate
5-9. GENERAL.
repair.
a. Responsibilities. The maintenance responsibility
b. Handling of Disassembled Parts. A parts tray or
for the M3 Borescope is assigned to the direct support
suitable receptacle should be provided so that parts, as
instrument repair shop. All repair authorized at the direct
removed, can be placed in their respective positions in
support level with the exception of those maintenance
relation to the assembled M3 Borescope. Always keep
procedures noted in Chapter 3 should be performed by
the parts in their relative position until the M3 Borescope
an instrument repairman. Disassembly will be
is completely reassembled.