Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (CONT)
B--Before Operation
D--During Operation
A--After Operation
Interval
ITEM TO BE INSPECTED
Equipment
Item
Is not Ready/Available
No.
B
D
A
PROCEDURE
If:
2
EYEPIECE ASSEMBLY (Cont)
b. Clean exterior lens surface
of the eyepiece assembly with
denatured alcohol (item 1,
10, app D).
3
ADAPTER TUBE ASSEMBLY
a. Ensure the adapter tube sub-
The adapter tube sub-
assembly (1) rotates freely
assembly binds during
within the adapter tube
operations.
assembly (2).
b. On early configuration,
The adapter tube or the
check to see that electric
electric light control
light control (3) operates
is damaged to the extent
without binding and the
that neither 24-volt nor
circuit breaker(s) (4) stay
115-volt power can be
pressed in.
used to illuminate the
illuminating head
assembly.