Section IV. COLLIMATION
5-7
GENERAL
This section describes the setup and use of the collimation standard to focus and inspect the alinement device.
5-8
COLLIMATION AND INSPECTION
This task covers:
a. Setting up and adjusting the collimation standard
b. Focusing the alinement device.
INITIAL SETUP
Test Equipment:
Tools - Continued:
Azimuth Test
Shop Equipment, Instrument and Fire Control
Fixture
P/N 7691596
System Repair: Field Maintenance (SC 5180-
95-B29)
Collimation
Standard
P/N 9388622
Materials:
Dial Indicator
P/N MIL-1-18422
Sharpening
Item 9,
Stone
Infinity
Collimator
P/N 5549108
Masking Tape
Item 10,
Mirror
P/N 10558251
V-blocks
P/N GGG-V-191
Tools:
Shop Equipment, Instrument and Fire Control:
Field Maintenance, Basic (SC 4931-95-A07)
5-18 Change 1