TM 9-4931-710-14&P
5-6
OBJECTIVE CELL ASSEMBLY MAINTENANCE INSTRUCTIONS-CONTINUED
CLEANING
REPAIR
Repair is by replacement of authorized parts as required
Clean all parts per TM 9-254.
REASSEMBLY
B
Burr four holes (1).
C
Install objective lens (3) in cell (2), concave side
first.
D
Install spacer (4), flat side out.
E
Install objective lens (5) with flat side against
spacer (4).
F
Spot sealing compound in four places, equally
spaced, to secure objective lens (5) to inside
diameter of cell (2).
G
Apply a coat of grease (Item 6, Appendix D) to new
packing (6). Install new packing (6) and retaining
Note
ring (7).
If the four sealant holes
H
Secure objective lens (3) in place by applying
have not been drilled in the
sealing compound to lens (3) through four holes
cell, begin with step A. If
(1).
they are present, proceed to
step C.
A
Drill four 1/8-in. diameter holes (1) in cell (2) 9/16
inch from the threaded end.
Note
Burrs must be removed
from the inside diameter of
the cell, to ensure the
objective lens can be
positioned properly.
Change 1 5-17
|