5-4 M139/M139A1/M140/M140A1/M154 ALINEMENT DEVICE MAINTENANCE INSTRUCTIONS-CONTINUED
DISASSEMBLY - CONTINUED
NOTE
Authorized to use and repair tritium models
but cannot procure a new one.
If tritium ID label is lost (or light source fails)
or radioactive ID plate is lost or needs to be
replaced, convert device to an A1 model.
Remove tritium light source and replace it
with ERLS light source, and new ID plate.
WARNING
The cap assembly contains
tritium gas (H3). A radiation
hazard will exist if a light
source is broken.
When maintaining alinement
device, follow radiation
hazard procedures on
warning page.
C Remove two screws (11), two washers (12), and
instruction plate (13).
D Remove cap assembly (14 or 14.1) and packing
(15) from battery pack. Discard packing.
E Remove two screws (16), two washers (17), and
identification plate (18).
F Peel off instruction plate (19) and decal (20).
Change 3
|