TM 9-4931-583-30&P
(2) Attach rigid casters (14) to base assembly
(1) TSU-GSE boresight alignment device
(16) using four bolts (13) with washers (11) under bolt
assembly. Refer to figure C-10 for breakdown and
parts identification numbers.
heads and nuts (10), with washers (12) under nuts.
(a) Remove pin (1) from knob (2).
(3) Connect five quick release pins (2) to chains
(b) Remove plate (5) and washer from pin (3)
(6).
and knob (2).
(4) Screw knob (28) into each side of vertical
(c) Remove knob (2) from block.
support assembly (20).
(d) Remove screw (7) and washer (8) and
Repair of Boresight
Assembly
remove knob (6) and cable (9).
Miscellaneous Components.
(2) Shelf assembly, pilot. Refer to figure
Expendable Supplies and Materials List
C-10 for breakdown and parts identification
numbers.
Part No./
Nomenclature
Specification
(a) Remove jam nut (29) and remove bolt
(32) from each corner of shelf assembly (30).
Pads, Scouring
L-P-50,
(b) Remove second jam nut from bolt.
Type I, Class 1
Polyamide Epoxy Primer
MIL-P-23377,
(c) Remove bolt (31), nut (24), and washer
Class 2
(25) and remove clevis assembly (34) from bolt.
(d) Remove four screws (27), nuts (24), and
NOTE
washers (26) and remove mounting ring (28) from
shelf assembly.
Miscellaneous components are those com-
ponents that are part of BAGSE, but do not
mount on the boresight assembly. The com-
(3) Shelf assembly, gunner. Refer to figure
ponents are stored in case numbers 5,6, and
C-10 for breakdown and parts identification
7.
numbers.
Removal. Remove component from case.
a.
(a) Remove jam nut (58) and remove bolt
(66) from each aft corner of shelf assembly.
b. Dent Repair.
(b) Remove second jam nut from bolt.
(1) Using abrasive material, such as scouring
pad, remove paint from dent and surrounding area.
(c) Remove nut (59), washer (61), and screw
(60) and separate clevis (63) from bolt.
(2) If part is serviceable, paint cleaned area
(d) Remove quick release pin (56) and re-
with polyamide epoxy primer.
move post assembly (90).
(e) Disconnect pin (56) from cable (57).
NOTE
(f) Loosen jam nut (58) and eye bolt (89) from
Components cannot be repaired at this
post (90) and jam nut.
level if damage or wear exists to the
point that boresight alignment cannot
(g) Remove nut (59), washer (61), and screw
be accomplished using the component.
(60) and remove clevis (77) from lower end of post
c. Disassembly.
assembly (90).
|