TM 9-4931-381-14&P-1
FRAME 14
Connect W10 Cable:
CAUTION
Make sure connector (1) is unplugged from 115 V ac source
and power supply (2) is set to OFF before connecting W 10
cable (3) to TSTS (4) to prevent damage to the TSTS (4).
NOTE
Frames 14 and 15 are for preparation for operation as part
of a troubleshooting procedure.
Make sure TEST SET POWER switch (5) is set to OFF. Make sure circuit breaker
1.
CB1 (6) is closed.
Connect W10 cable connector P1 (7) to test set connector J13 PWR IN (8).
2.
Plug connector (1) into 115 V ac source. Plug power supply (2) into 115 V ac source.
3.
Set power supply ON/OFF switch (9) to ON. Set power supply voltage to 28 1 V dc
4.
and power supply current to maximum.
Make sure THERMAL MO DE switch (10) and THERMAL TEST switch (11) are set
5.
to OFF.
Set TEST SET POWER sw itch (5) to ON. Automatic self-test will now run. Wait
6.
15 seconds.
GO TO FRAME 15
Volume I
4-26
Change 1