Page Title: Table 3-5. DC Voltage Chart No. 3 - Condenser Leakage Test Circuits
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-4910-736-14&P
- Condenser Leakage Test Circuits
DC Voltage Chart No. 3
NOTE
All voltages are measured between point specified and pin E22 (instrument
ground) with DC VTVM.  Battery voltage is assumed to be 12 V. All voltages
are 20%.
FUNCTION switch position:
COND
CONDENSER switch position:
LEAK
Test leads:
Shorted together
WARNING
High voltage is present in this test. DO NOT TOUCH ANY
EXPOSED COMPONENTS.  Exercise extreme caution when
measuring voltage.  Set instrument to OFF during inspec-
tion.  For steps 3 through 7, use VTVM on 500 V scale.
Action:
Step
Action:
Test
Normal
voltage normal
voltage abnormal
voltage
point
no.
1
Q 13 In
Proceed to step 2.
Inspect copper side of printed
12 v
circuit board for open circuit
or cold solder on Q13 in
line.
2
Replace Q13.
Q 13 Out
Proceed to step 3.
7.5 v
Replace A2.
A2 + Out
Proceed to step 4.
500 v
3
Replace R18.
4
Proceed to step 5.
R18 open.
450 v
E9
450 v
Proceed to step 6.
Inspect wire between E26 and
E 26
5
E9.
6
450 v
Proceed to step 7.
Inspect wire from pin E26 to
E 25
lug 9 of section 1 rear of
CONDENSER switch S2.
a. Inspect wires leading from
E 25
0v
7
E24 and E25 to PUSH TO TEST
PUSH TO
TEST
switch S4.
b. Switch S4 defective.
switch
Replace S4.
acti-
vated