TM 9-4910-736-14&P
OPERATION INSTRUCTIONS
2-1.  INTRODUCTION.  This section contains procedures for operating the test
set.  It includes descriptions of controls and indicators, preoperation check-
out, condenser testing, coil resistance testing, and coil voltage testing.
2-2.  CONTROLS, INDICATORS AND ACCESSORIES.  Table 2-1 is a description of the
test set controls, indicators and accessories.  These items are illustrated in
Controls, Indicators and Accessories
Control, indicator or
index no.
Function
accessory
1
Provides a summary of test set
INSTRUCTION PLATE
operation, listing tests,
switch positions, and expected
results.
2
Technical Manual
Provides instructions for use
and maintenance of test
set.
Meter Ml
Multicolored scales as follows:
3
O to
(blue)
O to
(blue)
O to 30 KV (black)
0.05 to
(red)
LEAKAGE bar (green)
SERIES RES bar (green)
The above are used to indicate
various coil resistances and
voltage and condenser capaci-
tance, leakage and series
resistance.
4
Adjusts meter to zero for
ZERO ADJ OHM AND SERIES
condenser series resistance
RES potentiometer R103
and for coil resistance tests.
9-foot long lead for testing
COIL PICK-UP lead
5
coil voltage.
6
Safety switch, used during
PUSH TO TEST switch S4
performance of coil voltage and
condenser leakage tests, to
avoid exposure of personnel to
high voltage.  When personnel
are not in physical contact
with equipment under test, then
switch may be used to perform
test.