INSPECTION-Continued.
INSPECT DUST DETECTOR COVER, INLET AND OUTLET
ADAPTERS, AND FILTER RETAINING STRAP
NOTE
This procedure applies to
"clean air" turbosuper-
charger only.
Inspect dust detector cover (A) for
1.
cracks, scoring of mating surface
(B), and thread damage in tapped
holes (C).
2. Check adapters (D) and (E) for
cracks, distortion or thread damage.
Ensure both are clear of obstruction.
3. Inspect filter retaining strap (F)
for cracks, bends, and general
serviceability.
4. Replace any of these components if
damaged.