CAUTION
W h e n tightening nut, d o not attempt to keep generator shaft from
t u r n i n g by inserting a screwdriver or any other tool in between
fan blades.
T o do so could result in damage to fan.
(c) Slide fan (2) on shaft with fan fins facing generator, and
secure with self-locking nut (1).
T o r q u e nut to 30-35 pound-feet.
(d) Remove generator from vise.
f.
G e n e r a t o r Performance Test.
3-28