WARNING
While the rotor is being pressed out of the drive end housing
assembly, firmly grasp bottom section of rotor shaft to prevent
rotor from dropping.
Failure to do this could result in injury
t o personnel and damage to equipment.
(b) Apply pressure on top of rotor shaft to remove rotor (14) from
drive end housing assembly (21).
(c) Remove spacer (25) from outer seal (24).
(8) Remove stator (fig. 3-1).
(a) Remove stator (19) and drive end housing assembly (21) from
arbor
press.
Place assembly on top of antidrive end housing (9) so that
d r i v e end housing assembly (21) faces up and stator laminations fit flush
in pilot bore of anti-drive end housing to protect stator windings.
(b) Remove three rectifier leads from stator terminal studs, and
bend leads out of the way to provide access to stator terminal nuts.
(c) Remove three nuts (15) used to secure rectifier leads to
stator teminal studs.
(d) Remove three rectifier leads from stator terminal studs, and
bend leads out of the way to provide access to teminal insulator (18).
(e) Remove three nuts (15), washers (16), and six spring washers
(17) used to secure insulator (18) to stator terminal studs.
(f) Remove insulator (18) from stator terminal studs.
3-10
|