R o t o r Resistance T e s t .
Step 15.
Check resistance of rotor field circuit according
to figure 2-12.
I f ohmmeter reading falls outside 4.5-6.5 ohms,
r o t o r i s d e f e c t i v e . R e p l a c e rotor, reassemble
g e n e r a t o r in accordance with paragraph 3-3, and
g o to step 16.
NOTE
Replace stator only if all previous checks
i n d i c a t e that all generator components
were not defective.
I f ohmmeter reading is between 4.5-6.5 ohms,
r o t o r i s n o t d e f e c t i v e . Replace stator,
r e a s s e m b l e generator in accordance with
p a r a g r a p h 3-1, and go to step 16.