TM 9-2920-252-34&P
3-11. LEAK TEST OF GENERATOR (CONT)
2. INSTALLATION OF ADAPTER PLATE.
NOTE
Adapter plate will usually be mounted
to engine (for generator installation) or
to packaging disk (for storage).
a Install new gasket(1)into groove in inner face of
adapter plate (2).
b. Loosen coupling clamp (3) as necessary and slide
into generator housing (4).
c. Position end of generator housing (4) against
adapter plate (2) and move coupling clamp (3)
into position. Tighten clamp by turning nut (5) to
torque stamped on the outer band of the clamp.
TA315019
3-21/(3-22 blank)
|