TM 9-2920-252-34&P
3-11. LEAK TEST OF GENERATOR (CONT)
1. LEAK TEST SETUP.
f. Close chamber shut-off valve and begin timing a
a. Install cover of test fixture with preformed packing
two-minute interval.
and secure in place with clamp.
g. At end of two-minute inverval, note loss of
b. Install plug and preformed packing in oil pump
pressure. If loss of pressure does not exceed 3
supply port.
psi, the waterproofness of generator is
acceptable.
c. Install fittings with preformed packing into oil
outlet port, and connect tubing between fittings
h. Use soap solution applied to seal areas of
and tee on cover.
generator while pressurized to 10 psi to locate
any source of excessive leakage.
d. Close-connect
a
measured
chamber
of
approximately one cubic foot with a 0-10 psi
i. If source of excessive leakage is a sealed area
pressure gage and a shut-off valve at its input to
that is authorized for DS/GS maintenance,
remaining port of tee on fixture cover.
disassemble and re-assemble with new seals as
applicable. Perform leak tests again.
e. Pressurize generator and chamber with dry air to
10 psi.
TA315018
3-20
|