3-7. DISASSEMBLY (CONT)
3. OIL PUMP ASSEMBLY.
CAUTION
Do not disturb setting of oil pressure
adjusting screw in oil pump assembly.
If generator is received with lockwire
broken, oil pump assembly must be
replaced. Pump flow calibration can
be accomplished only at Depot level
(refer to DMWR 9-2920-252).
a. Cut lockwire (1) and remove from pump (2)
attaching socket head screws (3).
Discard
lockwire.
b. Remove four socket head screws (3) and
packings with retainers (4) from oil pump
assembly (2) and retaining plate (5). Discard
packings.
c. Remove oil pump assembly (2) with oil pump
drive shaft (6).
d. Remove preformed packing (7) from groove in
retaining plate (5).
Discard packing.
e. Remove oil pump drive shaft (6) from oil pump
shaft (8).
f. Remove preformed packing (9) from internal
groove in bore of drive shaft (6).
Discard
packing.
g. Remove key (10) from oil pump shaft (8).
TA315010