SECTION II. EQUIPMENT DESCRIPTION AND DATA.
Friction damper assembly pressure is controlled by spring
1-6. GENERATOR DESCRIPTION.
(18) within the shaft assembly.
a. General. The generator is a heavy-duty, 28 volt,
650 ampere, oil cooled, brushless, direct current type
(converting mechanical input energy to an alternating
(2) The generator is designed to an eight pole
current which is rectified within the unit to produce a direct
configuration, with salient pole, rotating field for optimum
current output) engine accessory.
performance. Two three-phase stator windings, separated
in phase relationship by thirty electrical degrees, are each
connected to a separate three phase, bridge connected
(1) The generator uses filtered oil from engine
rectifier assembly.
main gallery line for cooling. Oil circulation is provided by
a pump integral with the generator and equipped with
appropriate bypass valve to limit the oil pressure and
(3)
The drive end and anti-drive end ball
flow.
bearings (13 and 21) are sealed and permanently
lubricated.
(2) The generator is completely enclosed and
waterproof. It will continue to function properly even if
(4) The oil pump assembly (22) is located at
completely submerged in water.
the anti-drive end and is driven from the rotor shaft
through an intermediate oil pump drive shaft (20). This
intermediate shaft is driven by the rotor shaft through a
NOTE
telescoping spline drive. The intermediate shaft, in turn,
Reference
numbers
shown
in
is coupled to the input shaft of the oil pump with woodruff
parentheses refer to the sectional view
key (23).
of the generator (Figure 1-1).
1-7. VOLTAGE REGULATOR DESCRIPTION.
b. Construction. The generator consists of six main
a. The  voltage  regulator  used  with  this
subassemblies: drive shaft assembly (19), exciter field
generator is transistorized and completely static except
assembly (9), main generator field assembly (6), main
for a circuit breaker. The circuit breaker is reset manually
generator rotor (4) and exciter rotor assembly (7), end bell
be means of an external toggle switch type lever (Figure
assembly (1), and oil pump assembly (22).
b. The regulator is completely enclosed and
(1) Drive shaft assembly (19) consists of a
waterproof.
flexible drive shaft and a friction damper assembly.
Flexibility is obtained with a telescoping type design.