|
|
All
Example 2:
If the number of
erations are listed in this column.
dimensions listed are in inches unless oth-
equipments supported is 89, and
erwise specified. For further identifica-
the allowance factor for 100
equipments is 3.4, the follow-
or manufac-
tion, the materiel
agency
ing computation would be made:
turer's part number is parenthetically
listed at the end of each nomenclature.
Unit of Issue.
The Unit of Issue
e.
column lists the actual unit of issue for
In this instance, the result
each item (ea, ft, bulk, etc.).
is rounded to the next lower
whole number since the frac-
Quantity Incorporated in Unit. The
f.
tional value is less than 0.5
Quantity Incorporated in Unit column in-
and the echelon would be au-
dicates the number of these parts required
thorized a quantity of 3.
for the particular use indicated.
5.
How To Find Parts
15-day Maintenance Allowance Per
g.
100 Major Items. No quantities are listed
Parts may be located by referring to the
in these columns.
Refer to TM 9-2300-
Table of Contents which lists the titles
223-34P for allowance factors for items
of all illustrations.
to be stocked. If any item appears here-
Refer to paragraph
2, in this appendix, for an explanation of
in and is not listed in TM 9-2300-223-34P,
illustration and text relationship.
it can be requisitioned as required for
immediate use only.
6. Abbreviations and Symbols
Depot
Maintenance
Guide
Per
100
h.
Abbreviations.
Major Items.
a.
(1)
This column lists the guide
alw -------------------------- allowance
assy --------------------- assembly(ies)
quantity factors for the repair
br -------------------------------
brass
parts recommended for the re-
build of 100 major components
cd- or zn-chromate-fin. -- cadmium or zinc
chromate finish
and/or major end items.
cd- or zn-pltd ---------- cadmium or zinc
plated
The quantities indicated in this
(2)
cop. ----------------------------
copper
column are for initial requisi-
DA --------------- Department of the Army
tion.
They will be revised by
dir _____________________________ direct
the depot organization to con-
ea ------------------ - ------------- each
form to actual usage, which may
ech -------- --------- ----------- echelon
be more or less than the quan-
----------------------- for example
tities indicated herein.
e.g.
equip. -----------------------
equipment
---------------------- and so forth
etc .
Since the allowance factors are
(3)
fig. ----------------------------
figure
based on 100 equipments, it is
fil-hd ------------------ fillister head
necessary to compute the exact
fl-hd ------------------------ flat head
quantity authorized. This quan-
FM ------------------------ field manual
tity is determined by the use
ft ------------- ------------- feet(foot)
of a simple mathematical for-
hex-hd -------------------- hexagon head
mula.
Resulting fractional
id -------- - ------------ inside diameter
values of 0.5 or larger will
be rounded to the next higher
i.e. --------------------------- that is
illust - - - - - - - - - - - - - - - - - - illustration
Fractional values be-
number.
in. ------------------------------- inch
low 0.5 will be rounded to the
next lower number.
----------------------- incorporated
inc
gen ----------------------------
general
If the number of
-------------------------------- long
Example 1:
lg
lt ----
------------------- light(weight)
equipments supported is 30, and
---------- ------------ maintenance
maint
the allowance factor for 100
equipments is 1.9, the following
med
-----------------------------
medium
NC ------------------- American National
computation would be made:
Coarse Thread
NF -------------------
American
National
Fine Thread
Since the resulting figure is
no. -----------------------:----7 number
od ------------------- outside diameter,
larger than 0.5, the echelon
would be authorized a quantity
olive drab
ORD - - - - - - - - - - - - - - - - - - - - - - - - - - - O r d n a n c e
of 1.
33
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |