TM 9- 2920- 232- 34&P / TO 38X14- 2- 32
-
-
-
- -
ASSEMBLY OF THE STARTER - CONTINUED
-
0010 00
5. Seating Used Brushes Assembly.
NOTE
New brushes will not require seating. Seating procedure applies to brushes which have been
run in some other location.
a. Seat any used brushes installed as follows:
1) Wrap commutator (1) on armature (2) with no. 2/0 sandpaper strip (3), sand side out, and secure with
adhesive tape (4).
2) Temporarily install armature (2) in commutator end plate assembly (5) so that brush ends (6) are riding on
sandpaper (3).
3) Manually rotate armature (2) clockwise until the contact surface of each brush (6) has been seated 85 to
100 percent in accordance with illustration.
b. Remove sandpaper (3) and thoroughly clean armature (2) and brush holder assembly (7) to remove all
residue from the seating operation.
0010 00- 8
-
|