a. Check armature shaft and commutator. Replace if armature shaft bearing diameter exceeds 0.6835 to 0.6845
inch at commutator end and 0.6215 to 0.6230 inch at drive end. The diameter of the armature shaft bearing in
the lever housing shall not exceed 0.8225 to 0.8240 inch.
NOTE
Low resistance of armature windings and interconnection through commutator bars make any
and all commutator bars essentially the same circuit for this test.
b. Inspect armature for grounds with a test light by touching one of the test probes to the armature core and the
other probe to one of the commutator bars. If the test light glows, the armature is grounded and must be
replaced.
c.
Inspect armature for short circuits using a growler fixture. Place the armature in growler. Hold a thin strip of
steel, such as a hacksaw blade on the armature. While holding the steel strip in position, rotate the armature
slowly. A short circuit will cause the strip to vibrate. If a short circuit is found, replace the armature.