OPERATIONAL TESTING OF THE GENERATOR - CONTINUED
-
0011 00
j.
When generator has satisfactorily met all requirements of test procedure, install generator band assembly
(16) and gasket (17) as follows:
NOTE
While sealant is still wet, install gasket (17) in accordance
with the following steps.
1) For generators, 10889713 or 11642898, apply a thin coat of sealant as a stripe about 1/2 inch wide along
each edge (18) on one surface of band assembly (16) and gasket (17).
2) Install gasket (17), sealant side in, over brush access openings (19) of stator housing (11). Start wrapping
around housing (11) and finish with slight overlap of gasket ends (do not stretch gasket).
a) Gasket (17) must start and end--overlap on housing (11) between brush access openings (19).
b) Overlap must be positioned where it will be in the gap of installed band.
3) Install band assembly (16) with gap (20) positioned.
END OF TASK
0011 00-116 bl-ank
00-5/ 00- 5