Click here to make tpub.com your Home Page

Page Title: Install junction box cover plate
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9- 2920- 224- 34&P
-
-
-
ASSEMBLY OF THE GENERATOR - CONTINUED
-
0010 00
l.
Generators 10889713 and 11642898 must be made as waterproof as possible by applying a sealant during
assembly. Coat heads of bolts, terminal connections, all nuts, and areas around openings in junction box (2)
with sealant before installing junction box cover plate (32). Seal all openings into generator, as well as the
area between radio--noise capacitors and generator housing. Make sure sealant is applied generously. Allow
sealant to evaporate (dry) for a short period of time before installing junction box cover plate (32).
m. Install junction box cover plate (32) on junction box (2) as follows:
1) Generators 8717421 and 11642898: secure cover with eight washer screws (33). Torque to 18--24 Ib--in
(2.0 to 2.7 Nm).
2) Generator 10889713: attach engine ground terminal guard (36) with two washer screws (34) through
mounting holes in guard (36), holes in cover (32), and into junction box (2). Use six washer screws (35) in
remaining holes to complete attachment of cover. Torque to 18--24 Ib--in (2.0 to 2.7 Nm).
3) Generator 10889713: attach guard (36) to generator housing (12) with two washer screws (37) through
mounting holes in guard (36), mounting holes in junction box (2), and into generator housing (12). Torque
to 18--24 Ib--in (2.0 to 2.7 Nm).
0010 00- 6
-

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business