ASSEMBLY OF THE GENERATOR - CONTINUED
-
0010 00
2. Radio Interference Filter.
a. Apply RTV sealer to mounting flange of capacitor assembly (1). Tilt capacitor assembly (1) as necessary to
clear installed ground lead and move into position in junction box (2).
b. Install two washer screws (3) into corners of capacitor assembly (1) mounting flange which are closest to
curved side of junction box (2). Torque to 18--24 Ib--in (2.0 to 2.7 NSm).
c.
Apply RTV sealer to mounting flange of capacitor (4). Install capacitor (4) in junction box (2) and secure with
two washer screws (3) at corners of capacitor mounting flange which are closest to curved side of junction
box (2). Torque to 18--24 Ib--in (2.0 to 2.7 Nm).
d. Place generator ground lead (5) in position in junction box (2) and secure it with flat washer (6), new
lockwasher (7), and hexagon plain nut (8).
e. Torque nut (8) to 5--10 Ib--ft (6.8 to 13.6 Nm) while holding ground lead (5) to keep it from rotating out of
correct position. Install flat washer (9) and new hexagon self--locking nut (10) finger tight.
0010 00- 4
-