DISASSEMBLY OF THE GENERATOR ASSEMBLY - CONTINUED
-
0008 00
br. Note location of indexing key (71) in receptacle assembly. Remove four screws (72) and lockwashers (73)
from receptacle assembly (74). Remove receptacle assembly from connector shell (75) using care to avoid
damage to wire leads. Discard lockwashers.
bs. Remove and discard receptacle assembly gasket (76).
bt. Remove four screws (72) and lockwashers (73) from connector shell (75) and separate shell from fan housing
(60). Discard lockwashers.
bu. Remove and discard shell gasket (76).
bv. Remove two plugs (77) from fan housing (60), two brush caps (78), and brush assemblies (79).
NOTE
Spring tension for brushes in fan motor is critical. Springs
are integral with brushes for fan motor.
bw. Check brushes and springs for cracks or breaks. New brush length shall be within 0.812 to 0.813 inch
dimension limits. Field wear limit is 0.250 inch. If any brushes or springs are defective, replace entire set.
71
0008 00- 18
-