TM9-2835-255-34
ACCESSORY GEARBOX CLEANING AND REPAIR (Sheet 27 of 40)
ACCESSORY GEARBOX COVER PLUG REPAIR
REMOVAL:
1. REMOVE AGB (ACCESSORY GEARBOX ) COV-
ER ASSEMBLY (1) (PAGE 7-49).
2.
REMOVE RETAINING RING (2).
CAUTION
Cover (1) is heavy. Use caution when
turning cover to prevent injury to fingers.
3. TURN COVER ASSEMBLY (1) UPSIDE DOWN
ONTO TWO BLOCKS OF WOOD.
a.
Position blocks of wood between the work
surface and the cover assembly (1) to prevent
damage of hardware protruding from the cov-
er assembly.
4. USING SLEEVE AND SOFT MALLET, PUSH
METAL RING (4) FROM THE AGB COVER ASSEM-
BLY (1). DISCARD PACKING (3).
INSPECTION:
1. INSPECT METAL SEAL RING BORE AND RE-
TAINING RING GROVE FOR EVIDENCE OF DAM-
AGE. IF DAMAGED, REASSEMBLE THE AGB US-
ING ORIGINAL HARDWARE AND REPLACE AGB
2. INSPECT THE METAL SEAL RING (4) FOR
SCORING, CRACKS OR DENTS. IF DAMAGED,
REPLACE METAL SEAL RING (4).
Go on to Sheet 28
7-72
Change 6
|