POWER TURBINE STATOR (PTS) POWER TRANSFORMER REPLACEMENT (Sheet 2 of 5)
REMOVE FOUR BOLTS (1) AND SEP-
4.
ARATE CONNECTOR (2) FROM THE
FLANGE CONNECTOR ELBOW (3).
.5 .
EXTRACT WIRES AND PINS (4,5.6.7)
FROM CONNECTOR (2).
a. Using pin extractor and installation tool.
remove the following wires and pins from
the backside of the connector (2): P
(white/green) (4), R (white/grey) (5), S
(white/yellow) (6) and T (white/blue) (7).
6.
ATTACH A 30 INCH NONELECTRICAL.
PULL THROUGH WIRE (8) WITH KNOT
AROUND EXPOSED PINS (4,5,6,7) OF
LOOSE WIRES. COVER KNOT AND
WIRES WITH TAPE TO FORM SMOOTH
SURFACE.
Go on to Sheet 3