TM 9-2835-255-34
LOW PRESSURE TURBINE NOZZLE REPLACEMENT (Sheet 2 of 11)
REMOVAL:
CAUTION
Do not lean against, hang anything on,
bump or rock low pressure (LP) turbine
rotor shaft (1). Damage to No. 5 bearing
air and oil seals may result.
1. USING A MARKER, PLACE ALIGNMENT MARKS
(2) ON POWER TURBINE (PT) HOUSING (3),
SPACER RING (4) AND LP TURBINE NOZZLE (5).
WARNING
Use caution when removing nozzle (5).
Rotor (1) will fall free without nozzle (5) in
place and could cause personnel injury or
damage to equipment. Have assistant
support rotor shaft (1) at all times during
removal of nozzle (5).
2. SUPPORT ROTOR SHAFT (1), CUT SAFE-I-Y
WIRE AND REMOVE 24 BOLTS (6). RETAIN BOLTS
(6) FOR FURTHER USE.
NOTE
Penetrating oil can be used to soak 24
bolts (6) to facilitate their removal.
CAUTION
Do not use a hammer to dislodge nozzle
(5). Damage to nozzle could result. Use
jacking bolts.
Go on to Sheet 3
6-93
Change 6
|