3-2. TROUBLESHOOTING - CONTINUED
( 1 ) ES-38. MORE THAN ONE HALF OF
i. MAIN OIL PUMP MAGNETIC
PLUG - CONTINUED
M A I N OIL PUMP MAGNETIC PLUG IS
C O V E R E D WITH METAL CHIPS. NO
OTHER ROTATION OR METAL CHIPS
NOTED.  - CONTINUED
Supplies:
Tools:
Dry  cleaning  solvent  (Item  7,
General  mechanic's  tool
kit:
automotive (SC 5180-90-N26)
Wiping  rag  (Item  14,  Appendix  B)
Metal  pail  (Item  136,
References:
TM 20-1
A. Remove forward RGB scavenge
tube  assembly  (1)  and  screen
(2) (TM 20-1).
WARNING
B.
Pour  one  quart  of  dry
cleaning  solvent  through
scavenge tube assembly (1)
and  into  clean  pail.
C.  Check  solvent  in  pail  for
metal chips.
A re there metal chips in solven t?