TM
9-2835-255-34
3-2. TROUBLESHOOTING - CONTINUED
( 1 ) ES-38. MORE THAN ONE HALF OF
i. MAIN OIL PUMP MAGNETIC
PLUG - CONTINUED
M A I N OIL PUMP MAGNETIC PLUG IS
C O V E R E D WITH METAL CHIPS. NO
OTHER ROTATION OR METAL CHIPS
NOTED. - CONTINUED
Supplies:
Tools:
Dry cleaning solvent (Item 7,
General mechanic's tool
kit:
automotive (SC 5180-90-N26)
Wiping rag (Item 14, Appendix B)
Metal pail (Item 136,
References:
TM 20-1
A. Remove forward RGB scavenge
tube assembly (1) and screen
(2) (TM 20-1).
WARNING
B.
Pour one quart of dry
cleaning solvent through
scavenge tube assembly (1)
and into clean pail.
C. Check solvent in pail for
metal chips.
A re there metal chips in solven t?
CONTINUED ON NEXT PAGE