TM 9-2835-255-34
3 - 2 . TROUBLESHOOTING - CONTINUED
( 8 ) E S - 3 5 . LOW PRESSURE COMPRESSOR
h. LOW PRESSURE COMPRESSOR -
RUBS OR BINDS WHEN TURNED BY
CONTINUED
HAND, RUBBING OR BINDING IS FELT
WHEN TUBEAXIAL FAN BLADES OR
LEFT COOLING FAN BLADES ARE
TURNED BY HAND AND THERE ARE
METAL CHIPS IN THE OIL PUMP TO
OIL COOLER FLUID FILTER. -
CONTINUED
A. Remove forward RGB scavenge
tube assembly (1) and screen
(2) (TM 20-1).
WARNING
B. Pour one quart of dry
cleaning solvent through
scavenge tube assembly (1)
and into clean pail.
C. Check solvent in pail for
metal chips.
Are there metal chips in solvent?
CONTINUED ON NEXT PAGE