3-2. TROUBLESHOOTING - CONTINUED
h . LOW PRESSURE COMPRESSOR -
(4) ES-31. LOW PRESSURE COMPRESSOR
CONTINUED
RUBS OR BINDS WHEN TURNED BY
HAND AND MORE THAN ONE HALF OF
RAIN OIL PUMP MAGNETIC PLUG IS
COVERED WITH METAL CHIPS. -
CONTINUED
CONTINUED FROM STEP 2
CAUTION
Extreme care should be taken
when handling low pressure
turbine rotor shaft (1).
Banging, jarring or rough
handling will cause damage to
No. 5 b e a r i n g c a r b o n s e a l .
A. Lift end (2) of shaft (1)
slightly to center shaft
(1), then push shaft (1) in
to establish clearance
between power turbine disc
( 3 ) a n d n o z z l e  4) a n d t o
load No. 5 bearing ( 5 ) .
B. Turn shaft (1), listen and
feel for rubbing or binding.
Does shaft turn smoothly with no
unusual noises?
CONTINUED ON NEXT PAGE
3-244