TM
9 - 2 8 3 5 - 2 5 5-34
3 - 2 . TROUBLESHOOTING - CONTINUED
I
E S - 1 6 . EMFS FAULTY - CONTINUED
(1)
c . ELECTRO-MECHANICAL FUEL
S Y S T E M (EMFS) - CONTINUED
CONTINUED FROM STEP 4
5
Test for 35 to 60 ohms between
contacts A and B on EMFS-J33.
Did multimeter show between 35 and
6 0 ohms?
I
I
A. Replace EMFS (TM 20-1).
B. Verify problem is
solved.
I
6
Test for 30 to 60 ohms between
contacts e and f on EMFS-J33.
Did multimeter
show
between
30
and
60 ohms?
A. Replace EMFS (TM 20-1).
B. Verify problem is
solved.
7
Test for 40 to 110 ohms between
contacts c and d on EMFS-J33.
Did multimeter
show
between
40
and
1 1 0 ohms?
,