3 - 2 . TROUBLESHOOTING - CONTINUED
I
E S - 1 6 . E M F S FAULTY - CONTINUED
(1)
c. ELECTRO-MECHANICAL FUEL
S Y S T E M (EMFS) - CONTINUED
Supplies:
Tools:
Wiping  rag
(Item
14,
Appendix
B)
General  mechanic's  tool  kit:
automotive (SC 5180-90-N26)
References:
Digital  multimeter  (Item  144,
TM 20-1
TA1  continuity  test  probe  kit
(Item  143, Appendix  D)
Test  lead  set  (Item  145,
1
A.
If  installed,  remove  EMFS
(TM 20-1).
B.  Check  to  see  if  three
locking  pins  (1)  on  J33
connector  (2)  are  worn,
cracked  or  broken  off.
Are locking pins OK?
I
A. Replace EMFS (TM 20-1).
B.  Verify  problem  is
solved.
2
Check  connector  J33  (2)  for
missing  or  damaged  electrical
pins  (contacts).
Are  any  electrical
pins
missing
or
damaged?
CONTINUED ON NEXT PAGE