3-1. FAULT SYMPTOM INDEX - CONTINUED
ITEM
PAGE
PARAGRAPH
SYMPTOM
(NUMBER)
LOW PRESSURE
COMPRESSOR
(CONTINUED)
h.
(8)
LOW PRESSURE COMPRESSOR RUBS
ES-35
OR BINDS WHEN TURNED BY HAND,
R U B B I N G OR BINDING IS FELT
WHEN TUBEAXIAL FAN BLADES OR
LEFT COOLING FAN BLADES ARE
TURNED BY HAND AND THERE ARE
M E T A L CHIPS IN THE OIL PUMP
T O OIL COOLER FLUID FILTER.
h.
(9)
LOW PRESSURE COMPRESSOR RUBS
ES-36
OR BINDS WHEN TURNED BY HAND
AND MORE THAN ONE HALF OF
ACCESSORY GEARBOX (AGB) AND
MAIN OIL PUMP MAGNETIC PLUGS
ARE COVERED WITH METAL CHIPS.
h.
(10)
LOW PRESSURE COMPRESSOR RUBS
ES-37
OR BINDS WHEN TURNED BY HAND,
R U B B I N G OR BINDING IS FELT
WHEN TUBEAXIAL FAN BLADES OR
LEFT COOLING FAN BLADES ARE
TURNED BY HAND AND MORE THAN
ONE HALF OF ACCESSORY GEARBOX
( A G B ) AND MAIN OIL PUMP
MAGNETIC PLUGS ARE COVERED
WITH METAL CHIPS.
M A I N OIL PUMP
MAGNETIC
PLUG
i.
(1)
MORE THAN ONE HALF OF MAIN
ES-38
O I L PUMP MAGNETIC PLUG IS
COVERED WITH METAL CHIPS. NO
OTHER ROTATION OR METAL CHIPS
NOTED.
OIL PUMP TO
OIL COOLER
FLUID FILTER
j.
(1)
M E T A L CHIPS ARE PRESENT IN
ES-39
T H E OIL PUMP TO OIL COOLER
F L U I D FILTER. NO OTHER
ROTATION OR METAL CHIPS
NOTED.