Blower Maintenance Instructions (Cont)
NOTE
Six puller screws must be 1/4 in.-20 x
1-1/4 in. (32 mm) or longer.
(17) Install three screws and aline two
puller tools to rear end plate (29).
(18) Turn both puller screws (15) evenly
and remove rear end plate (29).
(19) Remove puller tool from rear end
plate (29).
(20) Remove two screws (26) from front end
plate (23).
(21) Tag front end plate (23) and indicate top. Tag
front end of blower housing (31) and indicate
top.
(22) Remove front end plate (23) by tapping with
mallet.
CAUTION
Handle rotors with care to avoid
scratching surfaces.
NOTE
Tag rotors before removal.
(23) Remove right rotor (32) and
left rotor (33).
|