12-4. FUEL INJECTOR TESTING (CONT).
(24) Push valve lever (28) down.
(25) Pull pump lever (2) and watch flow of test oil
passing through discharge line (11). When no
air bubbles pass through line (11 ), do next
step.
Push injector control rack (29) in to full fuel
(26)
position.
Position pump lever (2) so it points straight
(27)
up.
Move rocker arm engagement lever (27) to
(28)
forward position.
Pull pump lever (2) forward 40 to 80 times a
(29)
minute with steady strokes and read
maximum reference value from right hand
gage (30).
Injector (17) must be repaired (refer to
(30)
than 138 or more than 162.
Pull pump lever (2) forward several times
(31)
with steady strokes and observe spray pattern
produced by injector (17).
Injector must be repaired (refer to para 12-3)
(32)
if spray pattern is uneven or if test oil does
not break up into a fine mist.