Troubleshooting Malfunctions (Cent)
Table 2-3. Troubleshoothg
(Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
3. HARD TO START/STALLS AT IDLE SPEED/DOES NOT RUN SMOOTHLY.
Step 1. Check adjustment of exhaust valve clearances (para 19-2).
Adjust exhaust valve clearances (para 19-2).
TA357650
Step 2. Check for misfiring cylinders. Start engine. Hold injector follower (1) down with a
screwdriver to prevent operation of injector. If cylinder has been firing properly, cylinder
will miss with a noticeable change in sound and engine operation. If cylinder has been
misfiring, there will be no noticeable change. Check all cylinders and tag misfiring ones.
Remove tagged injectors (para 12-2).
Test and repair injectors (paras 12-3 and 12-4).
Step 3. Repeat check for misfiring cylinder(s).
If cylinder(s) still misfire, perform engine tune-up (para 19-2 through 19-9).
Step 4. Check engine compression (para 19-1 1). If compression values are not within allowable
limits, remove air box covers (para 3-5). Inspect compression rings through ports of cylinder
liners.
Replace damaged or broken compression rings (para 6-2 and 6-3).
|