TM
Section II RUN-IN TESTS
RUN-IN PROCEDURE
INITIAL START
NOTE
NOTE
Operate engine in following sequence for proper
Provide supply of clean fuel (item 9, Appx C). Make
break-in. A dynamometer may be used to load
sure engine contains proper
(LO 9-2350-267-12 or
engine.
LO 9-2350-256-12).
A Start engine (p 4-3).
Continuous operation at light loads for several
hours can result in poor piston ring seating, causing
B
Run engine for
to 20 minutes with no load.
higher than normal oil consumption.
C Run engine for 30 minutes at one-third load.
For DJBMA only, if bleeding of fuel system is
necessary, be sure the priming lever is returned to
D Run engine for 2 to 3 hours at two-thirds load.
the disengage position after bleeding. (Refer to page
E Stop engine (p 4-4).
|