TESTS AND ADJUSTMENTS (CONTINUED)
DELIVERY VALVE ASSEMBLY TEST (50)
A
Assemble delivery valve assembly (l), spring (2), and holder
(3) to valve test adapter (TSE 76226). Torque adapter to
VALVE TEST ADAPTER
lb- ft.
NOTE
Make sure all external connections are tight and
test stand is in good working order.
Attach valve test adapter
manually operated nozzle test
B
stand.
NOTE
Leaking delivery valve assembly can be corrected
by lapping valve seat to corresponding seat in de-
TEST STAND
livery valve body with
amount of lapping
compound (item 23, Appx C). Lapping compound is
VALVE TEST ADAPTER
to contact valve and body seats only. Thoroughly
clean
assembly following lapping operation.
c
Slowly increase pressure to 300 psi. A rapid pressure drop
indicates leakage past delivery valve seat.
D
Slowly increase pressure until valve opens. Valve must
open between 300 and 600 psi. If not, replace delivery valve
spring and test assembly again.
|